Uncategorized

pioneer 12,000 btu mini split installation manual

Hope we can get an answer ASAP. While some manuals may only call for 18 gauge wire it is always recommended to use 14 gauge 4 conductor wire (14/4) for most systems. then take the gauges off and release the rest. Do you just unhook the pump, screw the cap back on and then charge the lines? Thanks for the great how to article. Both the high and low side will need to be released. When disconnecting this will let a small bit of refrigerant out not allowing any air back into the system. I let it set for several hours. So I believe the high pressure valve should be closed but the low pressure side is opened while the pump is running. Thank you again. Pioneer WYS012-17 Air Conditioner Inverter+ Ductless Wall Mount Mini Split System Air Conditioner & Heat Pump Full Set, 12000 BTU 115V Summary Pioneer Mini Split systems are good units and a good fit for those looking for a low-cost solution to cooling and heating a space. DUCTLESS MINI SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP, Please read this manual carefully before installing. Some other basic tools will also be needed such as a drill, screwdrivers, and wrenches. Also when you boil the system down, or vacuum it down (water will boil under vacuum and be extracted from the system) vac it down, mark it on the gauge with tape, and leave it overnight. inverter++ models PIONEER AC WB, CB, RB, UB, FB SERIES INDOOR UNITS FOR MULTI SPLIT SYSTEM AIR CONDITIONER AND HEAT PUMP SERVICE MANUAL. If you use anything but the 16 foot lineset I would get a tech in to help you with that final part. (21 pages) Air Conditioner Pioneer Inverter+ WAS Series Installation Manual Solid core wire has been known to cause more issues. Installing the Pioneer Ductless Mini Split was not that difficult and falls into a handy person Do-it-yourself category. While it can be installed quickly it is best to go slow. Next, the copper line set needs to be screwed together. the reason that I ask is that in researching I thought that I had read elsewhere that you needed an additional ounce for each additional 6′. Ideal-Air 728184 2 x 16 x 36 Cement Equipment Pad, Mini split heating and cooling air conditioner heat pump systems, Our Picks for the Best Tri Zone Mini Split Systems, https://removeandreplace.com/2017/06/19/pioneer-air-conditioner-mini-split-error-codes-and-troubleshooting-guide/, https://www.youtube.com/watch?v=Dg-w2uAsEJE. Depending on your specific needs, you will easily find a model that suits you. The mounting bracket is on the back of the inside unit held in place with a Philips screw. The L1 and L2 go the circuit breaker for power. They come with most everything needed except tools and electrical wiring to a panel. If you are still wondering why this cost more, it is ductless which means they avoidthe energy losses that are likely to occur with air conditioning units that have ducts. It is soft and easily bendable. The ductless mini split system makes it possible to heat or cool your room with ease without worrying about the noise level. The refrigerant is in the outdoor unit that everything needs to be sealed before opening the valves. It should hold a negative pressure if not there is a leak that needs to be fixed. I recently installed a Pioneer 12000 BTU 230 Volt unit which I thought I would share how I install a mini-split. It has to physically be unplugged to turn it off. There are many units available from small 9000 BTU units to large 36000 BTU units. One problem I had was the wire color codes were not exactly the same as the wiring harness sent to me. or operating your new air conditioning system. Senville SENL-12CD Mini Split Air Conditioner Heat Pump. PIONEER Air Conditioner Ductless Mini Split System Charging Vacuum Port Adapter, Converts New R410a Style 5/16 SAE Service Ports to Accept Older 1/4 SAE Gauge Hoses. The valve to the vacuum pump is shut off on the gauges and refrigerant opened letting it into the system. If the outside location already has concrete it can simply be set on it. Anyhow your breaker is over sized should be 15amp. Hello I tried to turn the unit on and all I’m getting is beeping sound with a blinking number 88. Can you email me please. Budget 410a Manifold Gauges on Amazon give them a call if you have any questions. The blue side is for low pressure. Feel instant relief the moment you enter your room with Pioneer’s latest Diamante series high-wall mini split heat pump. Screw the nuts on by hand carefully making sure not to strip the threads. Power on the unit using the remote control. DUCTLESS MINI SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP 9,000 BTU/h. I’m installing a 18000btu unit and the the lines coming from the indoor unit have pressure behind If you are looking for a powerful and energy-efficient Pioneer mini split that doesn’t cost too much money, we recommend the WYS012GMFI19RL-16 model. Ductless DC Inverter High Wall Mounted Split Air Conditioning and Heating System. Did you bend the copper tubing by hand or did you use a tool for this? fyb cooling and heating version I bought one of these, Pioneer WAS/WYS 9000 but with a 33′ lineset, is the book correct that I need to add 16oz for additional foot, or in this case 17′ x 16oz= 272 ozs , that seems like a awful lot. You buy a can or tank of the refrigerant and using the gauge set you add more into the system. Using the proper mini split communication wire is critical to a properly functioning unit. 12,000 BTU 1.0 Ton 208/230V Ductless Mini Split Air Conditioner - Inverter, Heat Pump, Remote and 16 ft. Copper Line Set The Hessaire 12,000 BTU 1-Ton Mini Split The Hessaire 12,000 BTU 1-Ton Mini Split provides improved efficiency ratings up to 16.7 SEER and delivers high performance from the moment it's activated. 96 ($404.98/Item) $999.99 $999.99 SEER High efficiency 4. Name brand packages are also a good option but the price will reflect it. This is done by removing the caps and using an Allen key turning them to the left counter-clockwise. Next, the inside unit will need to be mounted onto a wall. How much does a mini split air conditioner cost? Most local codes require 14 gauge wire, so using something smaller will not pass inspection in many areas. At minimum, you’ll need things like: 1. breaker 2. electric cables 3. 1. (dual, triple, quad, and quint multi). I could have used 12 Gauge wire but had the larger 10 gauge from another project so used it. The right side shows the temperature when the unit is turned on. Find helpful customer reviews and review ratings for PIONEER Air Conditioner WYS012AMFI22RL Mini Split Heat Pump, 12000 BTU-110/120 V at Amazon.com. $638.99. 9,000 btu/h. I just did a Climate-Right mini split, it comes fully charged, both units, and you install the line set and that opens a valve. Be careful with the copper line set as it cannot be kinked or will block the flow of refrigerant. ( “Additional refrigerant/Liquid side 1/4″/per additional feet:0.16oz/ft”). through 36,000 BTU/h.. Inverter+ WAS Series air conditioner pdf manual download. Learn how your comment data is processed. I read through the instructions many times because of my install, it was limited space After running the pump for a while and you are ready to test for leaks do you shut off the pump and close the valve on the manifold? Ideal-Air 728184 2 x 16 x 36 Cement Equipment Pad I’m thinking about trying the Pioneer next because it’s a bit less expensive and has a better trouble shooting and install manual. Hook the wiring harness to the inside unit which is labeled 1,2,3 and ground. Pioneer also has excellent customer service. Whichever way a pad is set up be sure it is level and set the outside unit on top of it. Every install will be a bit different since electrical box locations, walls and other things can change a layout. But if you want a custom fit you need to cut the copper tubing to size, then place the flaring nut over the tubing and then flare the copper before you can attach it to the outside unit. Free shipping Here is one on Amazon Here is the unit I bought on Amazon 8 Reason a Furnace Will Not Work Fall and Winter Maintenance Tips, Our Picks for the Best Mini Split Air Conditioner. First, the mounting bracket will need to be screwed onto the wall and level. One should again observe the gauge to make sure there is no leak. I bent the tubing by hand. Capacity: 12,000 BTU/Hr. Operation Mode: Cooling and Heating.Capacity: 12,000 BTU/Hr. If so, how do I do that, where do I do that, and how much do I put in? After this you can evacuate the unit. The indoor units are sometimes shipped pressurized with Nitrogen. If it holds the vacuum there is no leaks and the refrigerant can be released. It does flash the temperature the unit is set on, can you turn the temperature down to 68-69 degrees and see if it comes on? The Pioneer wall mounted mini split systems come in a wide variety of BTU classes, ratings, and SEER values. then call customer service if you have more questions. AHRI-listed 6. When you buy a Pioneer Minisplit Ductless Mini Split Air Conditioner with Heater and Remote online from Wayfair, we make it as easy as possible for you to find out when your product will be delivered.Read customer reviews and common Questions and Answers for Pioneer Minisplit Part #: WYS012G-17 on this page. Puron or reon? Personally, I install a 20 AMP breaker close to the unit but this is a personal preference as long as it is on a 20 AMP breaker at the panel. I am getting ready to install one of these 1200BTU WYS012GMFI19RL You did not state the model # of yours. The wire should be stranded, not solid core. Also for: Inverter++ was series, Inverter++ wys series. Pioneer WYS012G-19 Wall Mount Ductless Inverter Mini Split Heat Pump, 12000 BTU-208/230 V By pioneer 9.8 View Product 9.8 2: PIONEER Air Conditioner Pioneer Mini Split Heatpump, 12000 BTU … Guess they need to update their listing. Adding coolant is pretty easy, albeit maybe expensive for a single job. Make sure to save this manual for future reference. There are some tools that will be needed such as a Vacuum Pump and Manifold Gauges. The gauge will show negative pressure, after sitting for 20-30 minutes if it goes back up to 0 there is a leak and it needs to be fixed. This all-new product line was designed and developed to bring a truly affordable heating and cooling solution without sacrificing any of the desirable features. fab: cooling only version My question is I have a 12000 BTU 230V Pioneer mini split with a 25′ line set and I think I will be using just about every foot of it. two, three, four, and five zones The copper ends came with a flare so I used them. Wae-wye series single split dc inverter air conditioner / heat pump systems (65 pages), Multi-split system air conditioner / heat pump. While it is no secret that split air conditionersare more expensive than portable or window type ones, they do come with a long list and wide variety of great specifications that only this type can do. You put a 20amp with with 10g wire. Install Kit for Mini Split Heat Pump Systems. Summary The model stands at 42 x 48 x 66 inches and weighs at 315 pounds. It starts at around 13 minutes into the video. I used a 3-inch hole saw to drill an opening for the refrigerant line and wiring to go to the outside unit. Hi there, it should hold the vacuum. I should have used the low side but was only testing for a vacuum and leaks. AURA Series – 9000 BTU, 12000 BTU, 18000 BTU and 24000 BTU – Installation Manual AURA SERIES – 9000 BTU, 12000 BTU, 18000 BTU and 24000 BTU – Remote Control Manual (New Version) AURA SERIES – 9000 BTU, 12000 BTU, 18000 BTU and 24000 BTU – Remote Control Manual PDF User Manual/Installation Manual for Pioneer WAE WYE AC Ductless Wall Mount Mini Split Systems. I never guessed that there were this many little things to factor when installing these units. A video is also posted at the bottom of the page of the install. Free shipping. https://www.youtube.com/watch?v=Dg-w2uAsEJE. Unit is level on pads now, just want to know if it needs to be secured with expansion bolts, etc.. Its not necessary as they don’t move but guess it couldn’t hurt. You are correct about the vacuum pump process. If you install a unit let us know how it goes.   9 times out of 10 its a shoddy braze job on the lines from the factory or errant dirt in the flared fittings, I have the same unit and the pipes that connect to the evaporator coil have completely corroded in less than a year is anyone else having this problem thanks it is also leaking freon and keeps freezing up because the pipes are corroded, Your email address will not be published. Let the vacuum pump run for 15-20 minutes pulling a vacuum. Free shipping. Tech at Pioneer said that I didn’t need to worry if I shortened the 16′. To extract coolant is easy peasy for a tech as he would have an empty bottle to capture the gas, again using the gauge set to connect the bottle. WYS Wall Mount Mini Split (16.0~18.0 SEER) (Indoor and Outdoor Units) WYS Wall Mount Mini Split (20.5~22.8 SEER) (Indoor and Outdoor Units) YN 22 SEER Multi Split Outdoor Units (Universal Match) (2, 3, 4 and 5 Zones) YN Multi Split System Indoor Sections (WS, CB, RB, UB, FB / 9~24K BTU) CYB Ceiling Cassette Split Ductless Exploded Parts Diagrams The wire harness will need to be fed in from the back. So for example if a unit comes with 16 feet of line set and you only need 10 feet you can avoid flaring by coiling up the excess.   Required fields are marked *. Let it sit for at least 20-30 minutes or more and be sure it holds a negative pressure. The line-set can be left rolled up in a loop close to the unit or if the line-set is shortened the unit can be checked with gauges to be sure it is operating correctly. Or is there another step that I’m missing. great video. two, three, four, and five zones Most HVAC companies will install a disconnect box which simply breaks the flow of electricity when work is needed on the unit. $64.00 to $ ... PIONEER 12000 BTU 19 SEER DC Inverter+ Mini Split Heat Pump Set 120V +10' Kit. Again follow the schematic that comes with the unit. If your don’t shorten the lines, you won’t need to re-flare them. There are some tools that will be needed such as a Vacuum Pump and Manifold Gauges. The prices of these models vary depending on the BTUs they offer. Service Manual for Pioneer A/C Model Numbers: Pioneer AC YN018GMFI16M2D, YN027GMFI16M3D, YN036GMFI16M4D Manuals Pioneer mini split … The remote actually isn’t doing anything.   Since the loudest parts of this 115-volt mini-split are located outside, you’ll hardly hear it running. https://removeandreplace.com/2017/06/19/pioneer-air-conditioner-mini-split-error-codes-and-troubleshooting-guide/. The system has a cooling capacity of 12,000 BTU per hour and a heating capacity of 12,000 BTU per hour. Here is the Vacuum Pump I bought on Amazon Be sure to mount the bracket on a good stud so the unit is secure. I have a question about my connection’s? With BTUs ranging from 9000 to 36000, you can cool a small bedroom or a large garage. Be sure to follow the Installation manual that comes with your unit. Is there a distance min max between the inside and outside units ? What pressure (and temperature) should the lines be when testing heat and cool mode? Has Energy Star approval 7. It needs a flat solid surface that is level to sit on. Here is a link to the Pioneer troubleshooting guide with error codes. Using manifold gauges and a pump hook up to the low-side port. There are many low-cost vacuum pumps and gauges which I bought some budget ones for the install. look on YouTube and read the directions. Thanks Earl. PIONEER Air Conditioner Pioneer Mini Split Heat Pump Minisplit Heatpump 12000 BTU-208/230 V. The unit will come with lots of information such as user manual and installation instructions. PIONEER Air Conditioner Ductless Mini Split System Charging Vacuum Port Adapter, Converts New R410a Style 5/16 SAE Service Ports to Accept Older 1/4 SAE Gauge Hoses. inverter+ and inverter++ models. What kind of refrigerant did you use? The first step is to layout where the unit will be located and run the electrical. also, you can download the manual and read the install instructions before you buy the product. Yes, after leaving the pump run for 15-30 minutes the pump and valve are shut off. If this happens to you simply be sure the wire color match inside and out. Disconnect the vacuum hose line after letting in refrigerant. Yes, after evacuating the system, turn off the pump and close the valve on the manifold. (1 Ton)Efficiency Rating: 21.5 S.E.E.R.Electrical Specification: 110-120 VAC, 1 Phase, 60 Hertz. Ductless DC Inverter High Wall Mounted Split Air Conditioning and Heating System. I think 20amp needs 12g wire For example, Red would be connected to the connector labeled 1 inside and outside. The amount of refrigerant would be fine. How close can I get and have it work? Pioneer® 18,000 BTU 19 SEER 230V Ductless Mini-Split Air Conditioner Heat Pump System Full Set Sale price $958 00 $958.00 Regular price $1,260 00 $1,260.00 Save … The WYQ012GMFI22RL is a ductless mini split air conditionerthat promises to provide comfort and heat in your home without the noise that standard ACs make, yet still able to operate efficiently and excellently. The unit comes as stated pre-charged for the expectation of a 16 foot lineset. Pioneer® 18,000 BTU 19 SEER 230V Ductless Mini-Split Air Conditioner Heat Pump System Full Set Sale price $958 00 $958.00 Regular price $1,260 00 $1,260.00 Save … HVAC How-To, Tutorials, Reviews, Information and More, Do-It-Yourself Mini Split air conditioners, PIONEER Air Conditioner Pioneer Mini Split Heat Pump Minisplit Heatpump 12000 BTU-208/230 V, ZENY 3,5CFM Single-Stage 5 Pa Rotary Vane Economy Vacuum Pump 3 CFM 1/4HP Air Conditioner Refrigerant HVAC Air Tool R410a 1/4″ Flare Inlet Port, Blue, ZENY Diagnostic A/C Manifold Gauge Set R134a Refrigeration Kit Brass Auto Service Kit 4FT w/Case, 1/4″ SAE Fittings. No there is no set distance, technically the amount of refrigerant that comes in the unit accounts for the 16 foot line-set, but this should not make much difference. Do-It-Yourself Mini Split air conditioners have become very popular since they are a good alternative to high-cost HVAC installations. Hook up the wiring harness to the outside unit. The unit I received needed to be on a 20 AMP breaker which can be run to an electrical panel or on its own box. 1/4 - 3/8 Dia. Can’t power it off, turn it down or up with it. through 36,000 btu/h. Once hand tight use a wrench to tighten them up and get a good seal. ETL-approved 5. Video Instructions View and Download Pioneer Inverter+ WAS Series installation manual online. Are you even aware that you are boun… Less would be better for me, but I am concerned the efficiency will drop. (dual, triple, quad, and quint multi) (29 pages), Dc inverter two,three,four and five zone multi split-type air conditioner heat pump (29 pages), Multi split system outdoor units/two, three, four and five zones (111 pages), Multi-split system air conditioner / heat pump. Did you have to flare the copper tubing before making the connections? There is a plastic protector that slides into the hole and protects the wiring and copper lines if needed. PIONEER Air Conditioner Pioneer Mini Split Heat Pump Minisplit Heatpump 12000 BTU-208/230 V. The unit will come with lots of information such as user manual and installation instructions. PIONEER 9000 BTU 20 SEER Mini Split A/C Heat Pump 115V 16Ft Full Install Kit. Pioneer® 12,000 BTU 19 seer 230v Ductless Mini-split with Air Conditioner & Heat Pump system full set Installation Kit Options: Choose an option 10Ft 16Ft (Default) 25Ft 33Ft 50Ft Without Installation … The connectors are located under the front panel under a pull out on the right side. For starters, thank you for making such an easy to follow video. Your email address will not be published. A/C disconnect box 4. some sort of mounting pad, brackets or concrete blocks/pad to put the outdoor unit on if necessary 5. insulation and … Do I need to add more refrigerant? I had to cut my hole on the other side – left – not right . If you decide to install a unit yourself be sure to read the instructions 2-3 times before starting. Once everything is installed the line set will need to be vacuumed out with a Vacuum pump. The wires, line set, and drain line all need to be fed out the 3-inch hole and the unit mounted on the wall bracket. I think the directions say when you release the refrigerant just do a little then check to make sure it hold. Wire gauge can be larger but not smaller. A 3-inch hole saw bit is also needed to drill a hole for the line set and wiring to go between the units. ZENY Diagnostic A/C Manifold Gauge Set R134a Refrigeration Kit Brass Auto Service Kit 4FT w/Case, 1/4″ SAE Fittings. Intelligent on-off technology enables Pioneer® products to automatically enter energy-saving mode on standby, cutting energy consumption from the normal 5W to 1W or 0.5W per hour, accounting for 80%~90% of energy savings. The AC’s high efficiency comes from the variable speed compressor driven by a DC inverter. It is the only service port on the unit. Ultimate Surge and Power Protection for Mini Split Systems. After 15-20 minutes turn off the vacuum pump and watch the manifold gauges pressure. $74.99. Be sure to follow the Installation manual that comes with your unit. The main thing when installing the line-set it to not kink the copper and screw it together carefully as to not strip the bolt threads. using either side shoes in the booklet that it is ok to do. through 12,000 btu/h. Its a blinking 88 with a wifi symbol to the right of it which is also blinking. I haven’t had any problems so not sure what the code is. Most Mini Split systems will need a 5/16″ Female Coupler to 1/4″ Male Flare to connect the manifold gauges to the unit. air conditioner / heat pump. This was not much of a problem as the inside and outside units are labeled 1-2-3 and ground. Once certain there is no leak the refrigerant can be totally released. Once the line-set has been tested for any leaks and has a vacuum the refrigerant can be released. A pad will be needed to set the outside condensing unit. I have a question about the evacuation process. Five Length Options. If you use a shorter or long lineset you will have to either extract coolant for shorter linesets, or add additional coolant for longer linesets. Always follow the manual that comes with your unit for the wire Gauge and breaker Amps. The instructions will also show the location and size of the hole needed through the wall. Be sure the connectors labeled 1-2-3 and ground match the inside wall unit. Mini Split Pad on Amazon I installed the 12000 BTU 230 Volt model which the instructions called for a 20 AMP breaker. The max distance is most likely 50 feet for the compressor motor. I am going to be installing the 9k BTU 120v today, Here is a video I did installing a Senville Mini Split which I showed the steps better. Any ideas as to what it could be? Otherwise start looking for your leak. Plan the install over a 1-2 day period and take your time. A hole will need to be drilled to run the line-set and wires to the outside unit. I have a 9000 BTU Pioneer WYS Series unit and would like to know if I need to bolt down the outdoor compressor to my concrete pad or just let the unit sit on the pad? Feed the line set and wiring out the hole and set the unit on the mounting bracket. If you have most of the tools on hand already, you’ll need to dish out at least $50 extra on top of the A/C. (19 pages), Manual will be automatically added to "My Manuals", Pioneer Inverter+ WAS Series Owner's Manual, Air Conditioner Pioneer WAS series Installation Manual, Air Conditioner Pioneer WAS Series Owner's Manual, Air Conditioner Pioneer RAB Series Installation Manual, Air Conditioner Pioneer WAE012AMFI15RL Service Manual, Air Conditioner Pioneer YN-M Series Installation Manual, Air Conditioner Pioneer YN020GMFI22M2D Installation Manual, Air Conditioner Pioneer WYD009AL3JAR-L Service Manual, Air Conditioner Pioneer YN020GMFI22M2D Service Manual, Air Conditioner Pioneer YN-M Series Owner's Manual, Air Conditioner Pioneer YN018GMFI16M2D Service Manual, Air Conditioner Pioneer WYD-GLFI SERIES Service Manual, Air Conditioner Pioneer WYN011-I Combined Installation / Operation & Maintenance / Service Manual, Air Conditioner Pioneer YN009GMFI22RPD Installation Manual, Air Conditioner Pioneer FAB Series Installation Manual, Page 8: Installation Summary - Indoor Unit, Page 12: Drill Wall Hole For Connective Piping. Can you explain the vacuum pump step in a little better detail? This is easy enough, simply take your time by rolling out the copper line-set and hand tightening the connections before using a wrench. For example, here it is hooked to the Red Gauge and the pressure is negative with the dial under the zero marker. If there is no pad one can be bought or a small cement pad can be poured. Anyhow i was looking up the wiring and breaker requirements for both units it says 15amp max breaker Be sure to follow the schematics that come in the manual or on the inside door for your unit. (adsbygoogle = window.adsbygoogle || []).push({}); Doesn’t the condenser need to be 12″ from the wall? Operation Mode: Cooling and Heating. Ductless mini split system air conditioner / heat pump 9,000 btu/h. Make s… How To Install Pioneer 12000 BTU 230 Volts Ductless Mini Split. Operates with a 2-line 208-230 VAC Standard L1-L2-G power 3.   ZENY 3,5CFM Single-Stage 5 Pa Rotary Vane Economy Vacuum Pump 3 CFM 1/4HP Air Conditioner Refrigerant HVAC Air Tool R410a 1/4″ Flare Inlet Port, Blue The owner of this website, hvachowto.com, is a participant in the Amazon Services LLC Associates Program, Amazon.com.ca, Inc, Amazon EU Associates Programme an affiliate advertising program designed to provide a means for sites to earn commission income (advertising fees) by advertising and linking hvachowto.com to Amazon properties including, but not limited to, Amazon.com, Amazon.ca, Amazon.co.uk, Amazon.de, Amazon.se, Amazon EU Associates Programme, Amazon.it, Amazon.es, Amazon.fr endless.com, myhabit.com, smallparts.com, or amazonwireless.com Amazon.ca, Amazon.co.uk and other sites worldwide. I assume you did not need to flare the copper tubing simply because you did not cut the tubing for a custom fit. Look at the back of the unit for were the line-set and wiring stick out for were the hole will need to be drilled. Electrical Specification: 208~230 VAC, 1 Phase, 60 Hertz. inverter++ models (13 pages), Yn-m series multi split system multi circuit outdoor units (2, 3 and 4 zones) service manual (122 pages), Wd indoor / yn outdoor units series dc inverter air conditioner dc inverter split wall-mounted ductless heat pumps (40 pages), Ductless mini split system air conditioner / heat pump, uab: cooling only version / uyb: cooling and heating version series flex mount, inverter plus and inverter plus plus models, 18,000-48,000 btu/hr (18 pages), Floor console mini split system

Subject To Houses, Burger Day Uk, Houses For Sale In California Los Angeles, Womens Health Associates Insurance, Facebook Messenger Grey Tick, Nautilus Adjustable Dumbbells, Dyson Vacuum No Suction From Wand, Newspaper Article Template Google Docs,